Medfusion 2010i Syringe Pump
The Medfusion 2010i syringe pump offers flexibility for a variety of clinical needs, settings and applications. The pump may be utilized whenever meticulous low volume drug on fluid injections using a syringe are required.
-
We accept these cards
-
Return Policy
We have a 15 day return policy. Special orders are not returnable.
The Medfusion 2010i Syringe Pump may be field customized for specific applications.
A choice of 4 modes of delivery are available:
Body Weight Mode, Mass Mode, Continuous Mode and Volume Over Time Mode (dose volume/delivery time).
In addition, the pump has the ability to store up to 64 user regimens/protocols.
A bolus may be programmed, then changed or administered at any time prior to or during drug delivery.
The Medfusion 2010i FEATURES: * Programmable for four types of infusion - Body Weight Mode; Mass Mode; Continuous Mode; Volume Over Time Mode * Ability to store up to 64 user regimens/protocols
SPECIFICATIONS: * Flow rate: 0.01-378.0 ml/hr dependent upon syringe size
* Bolus rate: up to 378.0 ml/hr dependent upon syringe size
* Total Volume Delivered: 0.0000-9999 mg. ml or units
* Accuracy: +/-3% * Infusion Modes: Body Weight, Mass, Continuous and Volume/time * Accepts B-D, Monoject and Terumo syringes
* Accepts: B-D 1 TB, 1, 3, 5, 10, 20, 30, 60 ml Luer lock
* Monoject 1 TB, 3, 6, 12, 20, 35, 60 ml Luer lock
* Terumo 1 TB, 3, 5, 10, 20, 30, 60 ml Luer lock
* B-D (glass) 1, 3, 5, 10 ml
* Automatically adjusts the output PSI for different syringe sizes
* Automatically sense syringe size, syringe barrel placement and syringe plunger placement
* All syringes will fill to their maximum
* Power: AC-internal battery
* Recharge Time: No longer than 16 hours with the pump turned off
* Battery Capacity: at 25C a 16 hour charge will operate the pump for approximately 10 hours at 5.0 ml/hr with a 60 ml syringe
* At 25 degrees C a 16 hour charge will pump approx. 10 hrs at 5.0 ml/hr with a 60 ml syringe
* Alarms: Near Empty, Empty, Occlusion, System Malfunction, Low/Depleted Battery, Load Syringe Plunger, Check Clutch, Syringe Pops Out, Invalid Size, Invalid Number, Alarm Audio Volume, soft/loud, Alarm Temporary Delay
* Status Alerts: Stop/Program, Deliver, Battery In Use, Battery Charging, Priming, Back Light, Standby Mode, Bolus Delivery, End of Bolus
* Water resistant case * Suitable for arterial infusions
* Weight: 2.5 lbs. * 4.5” (w) x 3” (h) X 7.5” (w)
* Optional 220 volt AC charger makes this syringe usable throughout the world
Surgical Discounters offers a 15 day Return Policy and a 90 day Upgrade Policy. You must receive a "Return Authorization number" (RA) prior to returning merchandise
Unless otherwise specified, customers are responsible for properly packaging an insuring return equipment. Surgical Discounters reserves the right to void warranties or refuse repairs for merchandise not properly packaged and shipped by it's customers
Special orders are non-refundable.
Orders over $5,000 require a 50% down payment - balance due prior to shipment.
Established customers orders under $5,000 receive net 15 days.
Premium Website Members receive an additional 2% discount.
Surgical Discounters reserves the right to alter or change conditions on an individual basis.